BIOSAFE® GO: Mobile cryogenic workstation for sample handling in the nitrogen gas phase

With the BIOSAFE® GO, you can safely transfer biological and medical samples in vials, boxes, and racks; transport them within your biobank from one cryogenic vessel to another; and work directly on them. The vacuum-insulated cryogenic workbench with an integrated transport cart maintains a temperature of -130°C or colder for approximately 12 hours when the lid is closed.  

Substance
Temperature
Scope of application
BIOSAFE® GO - BIOSAFE® GO: Mobile cryogenic workbench for sample handling - img0
BIOSAFE® GO - BIOSAFE® GO: Mobile cryogenic workbench for sample handling - img1
BIOSAFE® GO - BIOSAFE® GO: Mobile cryogenic workbench for sample handling - img2
Service from the planning stage
until commissioning.
Rugged construction

BIOSAFE® GO images.

BIOSAFE® GO 0 - BIOSAFE® GO: Mobile cryogenic workbench for sample handling
BIOSAFE® GO 1 - BIOSAFE® GO: Mobile cryogenic workbench for sample handling

BIOSAFE® GO Features: 

The cryogenic workbench consists of a vacuum-insulated container mounted on a stainless steel transport cart. A filling device, measurement ports, and a data logger are included as standard equipment. 

  • Vacuum-insulated container on a stainless steel transport cart 
  • Two lid halves that open separately
  • Sliding sample-handling table 
  • Aluminum temperature booster for low temperatures in the working chamber
  • LN2 filling device with a 3/8" ball valve and a 2.5m long, insulated transfer hose 
  • Additional opening with a plug for level measurement 
  • Two ports for T-probes and mounting options for temperature loggers 
  • Data logger for temperature recordings 
  • 5 bar safety valve 
  • Transport plug 

Transferring and transporting samples in the gas phase 

The cryogenic workbench is designed for transferring samples within your biobank. You remove the samples from a cryogenic storage vessel and transport them to the destionation vessel within your facility. During transport, the samples remain in the cryogenic gas phase of liquid nitrogen, ensuring they stay cold throughout the whole time. 

Interior space for two horizontal racks 

The interior offers space for two horizontal racks. It is 1,020 mm long and 446 mm wide. With the lid closed, 385 mm of usable height is available; with the lid open, 450 mm. 

≤ -130 °C for approximately 12 hours 

A reserve of liquid nitrogen is located beneath the storage shelf. This maintains the temperature in the working chamber at -130°C or colder for approximately 12 hours when the lid is closed, as measured by the included data logger. An aluminum temperature booster helps maintain low temperatures in the working chamber. Refilling is performed via the LN2 filling device, which includes a ball valve and an insulated transfer hose. 

Documenting Temperature and Checking Fill Level 

The included data logger records the temperature during sample transfer or while working on the samples. Additionally, there are two ports for T-probes and mounting options for temperature loggers. Through a separate opening with a plug, you can mesure the liquid nitrogen fill level without having to open the lid. 

 

Work Ergonomically Right at the BIOSAFE® GO

The cryogenic workbench is designed as an ergonomic workbench with a working height of 930 mm. You can sort or work with samples directly on the cart using the sliding sample-handling table. The two halves of the lid can be opened separately. 

Cryogenic workbench, storage vessel, or dry shipper? 

The BIOSAFE® GO is a cryogenic workbench for transferring samples, performing short-term tasks, and transporting samples within your facility, rather than a storage vessel. The BIOSAFE® storage vessels are designed for long-term storage of your samples, while the BIOSAFE® MARATHON dry shipper is intended for shipping to other locations. 

Advantages of the BIOSAFE® GO

Workstation and Transport Cart in One:

  • Samples remain cold during transport: ≤ -130 °C for approx. 12 hours with the lid closed
  • Space for two horizontal stacks in an interior measuring 1,020 × 446 mm
  • Temperature recorded: Data logger included, two access points for T-probes
  • Work at a 930 mm operating height with a sliding sample-handling table
  • Check the fill level without opening the lid
  • Mobile within the facility on a stainless steel transport cart

Technical Specifications: BIOSAFE® GO Cryogenic Workstation

 BIOSAFE® GO
Geometrical Capacity (l) 265
LIN-Volume (l) approx. 20
Overall Dimensions (L x W x H) (mm) 1.465 x 625 x 975
Interior Dimensions (L x W x H) (mm)1.020 x 446 x 450
Opening Access (L x W) (mm) 1.030 x 446 
Usable height with lid closed (mm) 385
Operating heigt (mm) 930
Filling height (mm) 80
Temperature in the working chamber with lid closed≤ -130 °C for approx. 12 h
Evaporation rate* 1,5l/h
Weigth, empty (kg) 160
Weight, filled with LN2 (kg) 176
Castor diameter (mm) 125

*The evaporation rate was determined at 20 degrees Celsius and 1.013 hectopascals, with the container stationary and the lid closed. This is a nominal value that may vary depending on the containers's use and age. 

You can also find all information in our product brochure:

Options

Certifications

The BIOSAFE® GO is manufactured in accordance with AD 2000. Cryotherm is certified to EN ISO 13485:2016.

Certificates

Suitable for this
product:

BIOSAFE®

Cryopreservation at its best with our Cryocooler BIOSAFE®

BIOSAFE® GO: Mobile cryogenic workstation for sample handling in the nitrogen gas phase

With the BIOSAFE® GO, you can safely transfer biological and medical samples in vials, boxes, and racks; transport them within your biobank from one cryogenic vessel to another; and work directly on them. The vacuum-insulated cryogenic workbench with an integrated transport cart maintains a temperature of -130°C or colder for approximately 12 hours when the lid is closed.  

Please select a size:

Geometric capacity total [l]